SSH EN 60317-33:2016

Specifications for particular types of winding wires - Part 33: Glass fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 200

Sep 27, 2016

General information

60.60     Sep 27, 2016

DPS

DPS/KT 3

European Norm

29.060.10  

English  

Buying

Published

Language in which you want to receive the document.

Scope

IEC 60317-33:2015(E) specifies the requirements of polyester glass fibre wound, impregnated, bare or enamelled rectangular copper winding wire, temperature index 200. The range of nominal conductor dimensions covered by this standard is:

- width: min 2,0 mm max 16,0 mm;

- thickness: min 0,80 mm max 5,60 mm. The specified combinations of width and thickness as well as the specified width/thickness ratio are according to IEC 60317-0-4. This second edition cancels and replaces the first edition published in 1990, Amendment 1:1997 and Amendment 2:2005. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:

- new 3.2.2 containing general notes on winding wire, formerly part of the scope;

- introduction of glass fibre coverings over grade 1 enamelled conductor in 3.2.2;

- revision to references to IEC 60317-0-4 to make clear that their application is normative.
Keywords: temperature index 200, winding wire

Life cycle

NOW

PUBLISHED
SSH EN 60317-33:2016
60.60 Standard published
Sep 27, 2016

Related project

Adopted from EN 60317-33:2016

Adopted from IEC 60317-33 Ed. 2.0 en