Published
The purpose of this standard is to define the internal and/or external coatings of polyamide powders applied by dipping in a fluidised bed or by spraying, or by roto-coating. These coatings are intended for protecting the outer and inner surface of steel tubes and their fittings (components) used as pipeline component parts. This standard may be applied for accessories (such as valves, pumps, screens, etc ... ).
This type of coating is used for the protection of buried, submerged or above ground pipelines conveying fluids at working temperatures between 0 °C and + 60 °C. Other working service temperature may be used after agreement between the purchaser and the coater.
The coatings covered by this standard are applicable to longitudinally or spirally welded steel tubes and to seamless steel tubes and their fittings components used for the construction of pipelines conveying liquids.
The internal coating of tubes to be used for the transportation of water intended for human consumption shall not affect the quality of that water to such an extent that it fails to comply with the requirements of the EU and EFTA regulations.
For this purpose, reference shall be made to the relevant national regulations and standards, transposing EN standards when available, dealing with the influence of materials on water quality and to the requirements for coatings.
NOTE An European Acceptance Scheme (EAS) is in course of development in relation to the CPD and the DWD. Its requirements will be introduced in this standard when completed.
PUBLISHED
SSH EN 10310:2003
60.60
Standard published
Apr 28, 2005