DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

SSH EN 50176:2009

Stationary electrostatic application equipment for ignitable liquid coating material - Safety requirements

Nov 24, 2009

General information

60.60     Jan 1, 2009

DPS

DPS/KT 6

European Norm

87.100  

English  

Buying

Published

Language in which you want to receive the document.

Scope

1.1 This European Standard specifies the requirements for stationary electrostatic application equipment for ignitable liquid coating materials and for hard to ignite liquid coating materials to be used in explosive atmospheres generated by their own spray cloud. A distinction is made between spraying systems corresponding to EN 50050 and spraying systems designed for higher discharge energies and/or currents.
This European Standard also specifies the design-related requirements for a safe operation of the stationary equipment including its electrical installation.
1.2 This European Standard considers four types of electrostatic spraying systems; see 5.1 for more details.
1.3 This European Standard deals with all hazards significant for the electrostatic spraying of coating materials, which could also contain small quantities of added metal particles, if the work is carried out under conditions recommended by the manufacturer. In particular, this includes ignition hazards resulting from the generated explosive atmosphere, and the protection of persons from electric shocks.
1.4 This stationary equipment is classified as equipment of group II, category 2G or category 3G for use in potentially explosive areas of zone 1 or 2, respectively.
NOTE For other safety aspects like
– zone classification of the areas in and around spray booths, see EN 12215:2004, 5.7.2.3;
– zone classification of other areas with explosive atmosphere, see EN 60079-10-1;
– selection, installation and application of other electrical and non electrical equipment in areas with explosion hazard, see EN 60079-14 and EN 12215:2004, 5.7.2.5;
– health protection (for instance, noise), see also EN 12215:2004, 5.5 and EN 14462;
– cleaning of spraying areas, see instruction manual of the spraying equipment;
– fire prevention and protection (for instance fire hazards due to other sources) see also EN 12215:2004, 5.7.1.
Design-related measures for reducing the generation of noise of the stationary equipment for electrostatic coating are given in EN ISO 11688 1. See also EN 14462.

Related directives

Directives related to this standards.

94/9/EC

Equipment and protective systems intended for use in potentially explosive atmospheres (ATEX)

Harmonized
2014/34/EU

Directive 2014/34/EU Of The European Parliament And Of The Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (recast)

Harmonized

Life cycle

PREVIOUSLY

WITHDRAWN
SSH EN 50176:1996

NOW

PUBLISHED
SSH EN 50176:2009
60.60 Standard published
Jan 1, 2009

Related project

Adopted from EN 50176:2009