SSH ISO 11119-2:2002

Gas cylinders of composite construction — Specification and test methods — Part 2: Fully wrapped fibre reinforced composite gas cylinders with load-sharing metal liners

Jan 1, 2008
95.99 Withdrawal of Standard   Jun 24, 2019

General information

95.99     Jun 24, 2019

DPS

DPS/KT 269

International Standard

23.020.35     23.020.30  

English  

Buying

Withdrawn

Language in which you want to receive the document.

Scope

ISO 11119-2 specifies requirements for composite gas cylinders up to and including 450 litres water capacity, for the storage and conveyance of compressed or liquefied gases with test pressures up to and including 650 bar. The cylinders are constructed in the form of a seamless metallic liner over-wrapped with carbon fibre or aramid fibre or glass fibre (or a mixture thereof) in a resin matrix, or steel wire, to provide circumferential reinforcement.
This part of ISO 11119 refers to fully wrapped composite cylinders with a load-sharing liner (i.e. a liner that shares the load of the overall cylinder design) and a design life from 10 a to non-limited life. For cylinders with design life in excess of 15 a, and in order for these cylinders to remain in service beyond 15 a, re-qualification of these cylinders is recommended.
This part of ISO 11119 does not address the design, fitting and performance of removable protective sleeves. Where these are fitted they should be considered separately.

Life cycle

NOW

WITHDRAWN
SSH ISO 11119-2:2002
95.99 Withdrawal of Standard
Jun 24, 2019

REVISED BY

PUBLISHED
SSH ISO 11119-2:2012

Related project

Adopted from ISO 11119-2:2002