DPS
Drejtoria e Përgjithshme e Standardizimit
Phone: +355 4 222 62 55
E-mail: info@dps.gov.al
Address: Address: "Reshit Collaku" Str., (nearby ILDKPKI, VI floor), Po.Box 98, Tiranë - Albania
Main menu

SSH EN 50065-4-6:2004

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-6: Low voltage decoupling filters - Phase coupler

Sep 28, 2007

General information

60.60     Jan 1, 2007

DPS

DPS/KT 5

European Norm

31.160     33.040.30     97.120  

English  

Buying

Published

Language in which you want to receive the document.

Scope

This European Standard applies to phase couplers in a mains communication system for phase to neutral voltage not exceeding 250 V a.c. and a nominal current not exceeding 125 A, intended for household and similar fixed installation including residential, commercial and light industrial buildings.
This European Standard applies to phase couplers used to control the coupling of communication signals between phases or sections of a mains communication system.
A “phase coupler” may be used to achieve coupling between the phases of a multiphase installation, or to provide bridging of signals around other system components.
The standard defines
 the requirements to ensure a minimum coupling between the sections, and
 the requirements to ensure no change on the safety of the electrical installation.

Life cycle

NOW

PUBLISHED
SSH EN 50065-4-6:2004
60.60 Standard published
Jan 1, 2007

REVISED BY

IN_DEVELOPMENT
prSSH EN 50065-4-6:2024

Related project

Adopted from EN 50065-4-6:2004